Trigger Settings#

Important

On this page, perform settings in the order: Start Setup -> Function Setting Barcode -> End Setup.

Scan Mode#

Level Trigger#

Scanning starts while the scan key is held down and ends after a successful decode or when the read timeout is reached.

../../_shared/_images/module-280/MD01.png

* Level Trigger#

Auto Sensing#

Scanning starts when image changes are detected and ends when the read timeout is reached.

../../_shared/_images/module-280/MD02.png

Auto Sensing#

Continuous Scanning#

Continuously read one or multiple barcodes. The same-code interval setting defines the decode order. Press and release the scan key to start or stop scanning.

../../_shared/_images/module-280/MD03.png

Continuous Scanning#

Same Barcode Read Mode#

In auto sensing, continuous scanning, and pulse trigger modes, you can configure how repeated reads of the same barcode are handled.

Note

By default, the same barcode is not read again within 500 ms. The interval can be set to 0~5000 ms, where 0 means no interval.

Suppress Repeated Reads

If the same barcode is read repeatedly within the suppression period, it is ignored and not output, and the timer restarts.

Interval Read

If the same barcode is read repeatedly within the interval, it is ignored and not output. It is output again after the interval expires.

Do Not Repeat Same Barcode

The same barcode is not output repeatedly.

Example: Suppress repeated reads of the same barcode within 100 ms.

  1. Scan “Start Setup”.

  2. Scan the “Suppress Repeated Reads” setting barcode.

  3. Scan the “Read Interval” setting barcode.

  4. Scan the 1 setting barcode in Decimal Digits.

  5. Scan the 0 setting barcode in Decimal Digits.

  6. Scan the 0 setting barcode in Decimal Digits.

  7. Scan “End Setup”.

Example: Read the same barcode again after a 1-second interval.

  1. Scan “Start Setup”.

  2. Scan the “Interval Read” setting barcode.

  3. Scan the “Read Interval” setting barcode.

  4. Scan the 1 setting barcode in Decimal Digits.

  5. Scan the 0 setting barcode in Decimal Digits.

  6. Scan the 0 setting barcode in Decimal Digits.

  7. Scan the 0 setting barcode in Decimal Digits.

  8. Scan “End Setup”.

../../_shared/_images/module-280/SDM1.png

* Suppress Repeated Reads#

../../_shared/_images/module-280/SDM2.png

Interval Read#

../../_shared/_images/module-280/SDM3.png

Do Not Repeat Same Barcode#

../../_shared/_images/module-280/SDT.png

Read Interval (ms)#

Decode Time#

(This setting is not supported in continuous scanning mode.)

../../_shared/_images/module-280/SBT1.png

* 5 Seconds#

../../_shared/_images/module-280/SBT2.png

10 Seconds#

../../_shared/_images/module-280/SBT0.png

No Limit#

Sleep Time#

../../_shared/_images/module-280/SPT0.png

Disable#

../../_shared/_images/module-280/SPT1.png

1 Second#

../../_shared/_images/module-280/SPT2.png

2 Seconds#

../../_shared/_images/module-280/SPT3.png

3 Seconds#

../../_shared/_images/module-280/SPT4.png

5 Seconds#

../../_shared/_images/module-280/SPT5.png

7 Seconds#

../../_shared/_images/module-280/SPT6.png

* 10 Seconds#

../../_shared/_images/module-280/SPT7.png

15 Seconds#

Auto Sensing Sensitivity#

../../_shared/_images/module-280/ITS1.png

Low Sensitivity#

../../_shared/_images/module-280/ITS2.png

* Medium Sensitivity#

../../_shared/_images/module-280/ITS3.png

High Sensitivity#

Decode Data Verification#

../../_shared/_images/module-280/DRC1.png

* Disable#

../../_shared/_images/module-280/DRC2.png

Output After Reading Twice#

../../_shared/_images/module-280/DRC3.png

Output After Reading Three Times#