Trigger settings#

reading mode#

Users can set the reading mode of the scan engine according to their needs. The default state is the button trigger mode. In this mode, the scan engine starts reading after pressing the trigger button, and stops reading after successful reading or releasing the trigger button.

../../_shared/_images/module-ccd/013300.png

* Key Trigger#

Users can also set the scan engine to automatic continuous reading mode. After the setting is successful, the red light of the scan engine is always on. When a barcode passes by, the scan engine automatically reads the barcode. The same barcode will not be read again unless it is removed and read again.

../../_shared/_images/module-ccd/013304.png

Automatic Continuous Reading#

../../_shared/_images/module-ccd/013305.png

Discontinuous Reading#

The user can also set the scan engine to the button delay mode. After the setting is successful, the red light of the scan engine will stay on for 3 seconds, and the light will turn off if the scan engine is not read after a timeout of 3 seconds, or the light will turn off after the reading is successful. The key timeout is

../../_shared/_images/module-ccd/013301.png

Key Delay#

Key Delay Parameters#

Key Timeout#

When the user uses the key delay mode, the user can set the decoding timeout according to the needs. The default is 3 s and the time range is 1-9.9 s.

../../_shared/_images/module-ccd/023510.png

Timeout 1 S#

../../_shared/_images/module-ccd/023530.png

* Timeout 3 S#

../../_shared/_images/module-ccd/023550.png

Timeout 5 S#

../../_shared/_images/module-ccd/023599.png

Timeout 9.9 s#

Self-sensing Settings#

../../_shared/_images/module-ccd/02310.png

* Disable IR Auto-sensing#

../../_shared/_images/module-ccd/02311.png

Enable IR Auto-sensing#

Self-sensing Sensitivity And Interval Time Parameters

Format

0265 + sensitivity setting + interval setting

Sensitivity

0x01 to 0xFF, the smaller the value, the higher the sensitivity.

Interval time

0x01 to 0x40.

Example

02657705 means the sensitivity is 0x77 and the interval is 0x05 (500 ms).

../../_shared/_images/module-ccd/02657705.png

Self-sensing Sensitivity And Interval Time Setting Example#

Inverse Color Reading Settings#

../../_shared/_images/module-ccd/00161.png

Enable Inverse Color Reading#

../../_shared/_images/module-ccd/00160.png

* Disable Inverse Color Reading#

../../_shared/_images/module-ccd/image46.png

Inverse Color Reading Settings#

Duplicate Code Detection Settings#

../../_shared/_images/module-ccd/02770.png

* Disable Duplicate Code Detection#

../../_shared/_images/module-ccd/02771.png

Enable Duplicate Code Detection#

../../_shared/_images/module-ccd/02630A.png

The Re-coding Interval Is 1s#

../../_shared/_images/module-ccd/026314.png

The Re-code Interval Is 2s#

../../_shared/_images/module-ccd/02631E.png

The Re-code Interval Is 3s#

../../_shared/_images/module-ccd/026332.png

The Re-coding Interval Is 5s#

../../_shared/_images/module-ccd/026364.png

The Re-coding Interval Is 10s#