Data Editing#

Important

On this page, perform settings in the order: Start Setup -> Function Setting Barcode -> End Setup.

Output format#

The following is the data output format.

Field

Length / Description

Barcode Information

4 bytes

Prefix

4 bytes

AIM ID

Barcode Data

Suffix

4 bytes

Terminator

1 byte

Barcode Information#

Important

For this procedure, perform settings in the order: Start Setup -> Function Setting Barcode -> End Setup.

  1. By default, barcode information is not output.

  2. Use a serial command or scan a setting barcode to enable or disable barcode information output.

Warning

This function is supported only in serial mode and is not supported in USB keyboard mode.

The format is defined as follows:

Field

Length / Description

Start Flag

0x03 (1 byte)

Barcode Symbology Code

1 byte, hexadecimal

Barcode Length

2 bytes, range 0x0001 ~ 0xFFFF

Barcode symbology codes are as follows:

Code

Barcode Type

0x41

PDF417

0x42

Micro PDF417

0x43

Data Matrix

0x44

QR Code

0x45

Micro QR

0x46

Aztec

0x47

MaxiCode

0x61

UPC-A

0x62

UPC-E

0x63

EAN-8

0x64

EAN-13

0x65

Code 128

0x66

Code 39

0x67

Code 93

0x68

Code 32

0x69

Code 11

0x6A

Codabar

0x6B

Plessey

0x6C

MSI Plessey

0x6D

Interleaved 2 of 5

0x6E

IATA 2 of 5

0x6F

Matrix 2 of 5

0x70

Straight 2 of 5

0x71

Pharmacode

0x72

GS1 DataBar 14

0x73

GS1 DataBar Expanded

0x74

GS1 DataBar Limited

0x75

Composite Code-A

0x76

Composite Code-B

0x77

Composite Code-C

../../_shared/_images/module-280/24I0.png

* Disable#

../../_shared/_images/module-280/24I1.png

Enable#

Prefix#

Important

For this procedure, perform settings in the order: Start Setup -> Function Setting Barcode -> End Setup.

Add output characters before barcode data. Up to 4 characters can be set.

Example: Add the character a before all barcode data

  1. Scan “Start Setup”.

  2. Scan the “Set Prefix for All Symbologies” setting barcode.

  3. Scan the a setting barcode in ASCII Code Table.

  4. Scan “End Setup”.

Example: Remove the prefix

  1. Scan “Start Setup”.

  2. Scan the “Disable Prefix for All Symbologies” setting barcode.

  3. Scan “End Setup”.

Example: Add the characters &13 before EAN-13 barcode data

  1. Scan “Start Setup”.

  2. Scan the “Set EAN-13 Prefix” setting barcode.

  3. Scan the & setting barcode in ASCII Code Table.

  4. Scan the 1 setting barcode in ASCII Code Table.

  5. Scan the 3 setting barcode in ASCII Code Table.

  6. Scan “End Setup”.

Example: Remove the EAN-13 prefix

  1. Scan “Start Setup”.

  2. Scan the “Disable EAN-13 Prefix” setting barcode.

  3. Scan “End Setup”.

../../_shared/_images/module-280/DP00.png

* Disable Prefix for All Symbologies#

../../_shared/_images/module-280/EP00.png

Set Prefix for All Symbologies#

../../_shared/_images/module-280/EP01.png

Set UPC-A Prefix#

../../_shared/_images/module-280/DP01.png

Disable UPC-A Prefix#

../../_shared/_images/module-280/EP02.png

Set UPC-E Prefix#

../../_shared/_images/module-280/DP02.png

Disable UPC-E Prefix#

../../_shared/_images/module-280/EP03.png

Set EAN-8 Prefix#

../../_shared/_images/module-280/DP03.png

Disable EAN-8 Prefix#

../../_shared/_images/module-280/EP04.png

Set EAN-13 Prefix#

../../_shared/_images/module-280/DP04.png

Disable EAN-13 Prefix#

../../_shared/_images/module-280/EP05.png

Set Code 128 Prefix#

../../_shared/_images/module-280/DP05.png

Disable Code 128 Prefix#

../../_shared/_images/module-280/EP06.png

Set Code 39 Prefix#

../../_shared/_images/module-280/DP06.png

Disable Code 39 Prefix#

../../_shared/_images/module-280/EP07.png

Set Code 93 Prefix#

../../_shared/_images/module-280/DP07.png

Disable Code 93 Prefix#

../../_shared/_images/module-280/EP08.png

Set Code 32 Prefix#

../../_shared/_images/module-280/DP08.png

Disable Code 32 Prefix#

../../_shared/_images/module-280/EP09.png

Set Code 11 Prefix#

../../_shared/_images/module-280/DP09.png

Disable Code 11 Prefix#

../../_shared/_images/module-280/EP10.png

Set Codabar Prefix#

../../_shared/_images/module-280/DP10.png

Disable Codabar Prefix#

../../_shared/_images/module-280/EP11.png

Set Plessey Prefix#

../../_shared/_images/module-280/DP11.png

Disable Plessey Prefix#

../../_shared/_images/module-280/EP12.png

Set MSI Plessey Prefix#

../../_shared/_images/module-280/DP12.png

Disable MSI Plessey Prefix#

../../_shared/_images/module-280/EP13.png

Set Interleaved 2 of 5 Prefix#

../../_shared/_images/module-280/DP13.png

Disable Interleaved 2 of 5 Prefix#

../../_shared/_images/module-280/EP14.png

Set IATA 2 of 5 Prefix#

../../_shared/_images/module-280/DP14.png

Disable IATA 2 of 5 Prefix#

../../_shared/_images/module-280/EP15.png

Set Matrix 2 of 5 Prefix#

../../_shared/_images/module-280/DP15.png

Disable Matrix 2 of 5 Prefix#

../../_shared/_images/module-280/EP16.png

Set Straight 2 of 5 Prefix#

../../_shared/_images/module-280/DP16.png

Disable Straight 2 of 5 Prefix#

../../_shared/_images/module-280/EP17.png

Set Pharmacode Prefix#

../../_shared/_images/module-280/DP17.png

Disable Pharmacode Prefix#

../../_shared/_images/module-280/EP18.png

Set GS1 DataBar 14 Prefix#

../../_shared/_images/module-280/DP18.png

Disable GS1 DataBar 14 Prefix#

../../_shared/_images/module-280/EP19.png

Set GS1 DataBar Expanded Prefix#

../../_shared/_images/module-280/DP19.png

Disable GS1 DataBar Expanded Prefix#

../../_shared/_images/module-280/EP20.png

Set GS1 DataBar Limited Prefix#

../../_shared/_images/module-280/DP20.png

Disable GS1 DataBar Limited Prefix#

../../_shared/_images/module-280/EP21.png

Set Composite Code A Prefix#

../../_shared/_images/module-280/DP21.png

Disable Composite Code A Prefix#

../../_shared/_images/module-280/EP22.png

Set Composite Code B Prefix#

../../_shared/_images/module-280/DP22.png

Disable Composite Code B Prefix#

../../_shared/_images/module-280/EP23.png

Set Composite Code C Prefix#

../../_shared/_images/module-280/DP23.png

Disable Composite Code C Prefix#

../../_shared/_images/module-280/EP24.png

Set PDF417 Prefix#

../../_shared/_images/module-280/DP24.png

Disable PDF417 Prefix#

../../_shared/_images/module-280/EP25.png

Set Micro PDF417 Prefix#

../../_shared/_images/module-280/DP25.png

Disable Micro PDF417 Prefix#

../../_shared/_images/module-280/EP26.png

Set Data Matrix Prefix#

../../_shared/_images/module-280/DP26.png

Disable Data Matrix Prefix#

../../_shared/_images/module-280/EP27.png

Set QR Code Prefix#

../../_shared/_images/module-280/DP27.png

Disable QR Code Prefix#

../../_shared/_images/module-280/EP28.png

Set Micro QR Prefix#

../../_shared/_images/module-280/DP28.png

Disable Micro QR Prefix#

../../_shared/_images/module-280/EP29.png

Set Aztec Prefix#

../../_shared/_images/module-280/DP29.png

Disable Aztec Prefix#

../../_shared/_images/module-280/EP30.png

Set MaxiCode Prefix#

../../_shared/_images/module-280/DP30.png

Disable MaxiCode Prefix#

Suffix#

Add output characters after barcode data. Up to 4 characters can be set.

Example: Add the character a after all barcode data

  1. Scan “Start Setup”.

  2. Scan the “Set All SymbologiesSuffix” setting barcode.

  3. Scan the a setting barcode in ASCII Code Table.

  4. Scan “End Setup”.

Example: Remove the suffix

  1. Scan “Start Setup”.

  2. Scan the “Disable All SymbologiesSuffix” setting barcode.

  3. Scan “End Setup”.

Example: Add the characters &13 after EAN-13 barcode data

  1. Scan “Start Setup”.

  2. Scan the “Set EAN-13 Suffix” setting barcode.

  3. Scan the & setting barcode in ASCII Code Table.

  4. Scan the 1 setting barcode in ASCII Code Table.

  5. Scan the 3 setting barcode in ASCII Code Table.

  6. Scan “End Setup”.

Example: Remove the EAN-13 suffix

  1. Scan “Start Setup”.

  2. Scan the “Disable EAN-13 Suffix” setting barcode.

  3. Scan “End Setup”.

Note

The source document does not provide extractable suffix setting barcode images for this section. The suffix options are listed below for now and can be restored to scannable items after the missing images are added.

Applicable Symbology

Setting Item

Disable Item

All Symbologies

Set Suffix for All Symbologies

* Disable Suffix for All Symbologies

UPC-A

Set UPC-A Suffix

Disable UPC-A Suffix

UPC-E

Set UPC-E Suffix

Disable UPC-E Suffix

EAN-8

Set EAN-8 Suffix

Disable EAN-8 Suffix

EAN-13

Set EAN-13 Suffix

Disable EAN-13 Suffix

Code 128

Set Code 128 Suffix

Disable Code 128 Suffix

Code 39

Set Code 39 Suffix

Disable Code 39 Suffix

Code 93

Set Code 93 Suffix

Disable Code 93 Suffix

Code 32

Set Code 32 Suffix

Disable Code 32 Suffix

Code 11

Set Code 11 Suffix

Disable Code 11 Suffix

Codabar

Set Codabar Suffix

Disable Codabar Suffix

Plessey

Set Plessey Suffix

Disable Plessey Suffix

MSI Plessey

Set MSI Plessey Suffix

Disable MSI Plessey Suffix

Interleaved 2 of 5

Set Interleaved 2 of 5 Suffix

Disable Interleaved 2 of 5 Suffix

IATA 2 of 5

Set IATA 2 of 5 Suffix

Disable IATA 2 of 5 Suffix

Matrix 2 of 5

Set Matrix 2 of 5 Suffix

Disable Matrix 2 of 5 Suffix

Straight 2 of 5

Set Straight 2 of 5 Suffix

Disable Straight 2 of 5 Suffix

Pharmacode

Set Pharmacode Suffix

Disable Pharmacode Suffix

GS1 DataBar 14

Set GS1 DataBar 14 Suffix

Disable GS1 DataBar 14 Suffix

GS1 DataBar Expanded

Set GS1 DataBar Expanded Suffix

Disable GS1 DataBar Expanded Suffix

GS1 DataBar Limited

Set GS1 DataBar Limited Suffix

Disable GS1 DataBar Limited Suffix

Composite Code A

Set Composite Code A Suffix

Disable Composite Code A Suffix

Composite Code B

Set Composite Code B Suffix

Disable Composite Code B Suffix

Composite Code C

Set Composite Code C Suffix

Disable Composite Code C Suffix

PDF417

Set PDF417 Suffix

Disable PDF417 Suffix

Micro PDF417

Set Micro PDF417 Suffix

Disable Micro PDF417 Suffix

Data Matrix

Set Data Matrix Suffix

Disable Data Matrix Suffix

QR Code

Set QR Code Suffix

Disable QR Code Suffix

Micro QR

Set Micro QR Suffix

Disable Micro QR Suffix

Aztec

Set Aztec Suffix

Disable Aztec Suffix

MaxiCode

Set MaxiCode Suffix

Disable MaxiCode Suffix

Barcode Identifier#

Important

For this procedure, perform settings in the order: Start Setup -> Function Setting Barcode -> End Setup.

../../_shared/_images/module-280/24D0.png

* Disable Barcode Identifier#

../../_shared/_images/module-280/24D1.png

Enable AIM Barcode Identifier#

../../_shared/_images/module-280/24D2.png

Enable NETUM Barcode Identifier#

Barcode Identifier Table

Symbology

NETUM

AIM

UPC-A

A

E

UPC-E

E

E

EAN-8

FF

E

EAN-13

F

E

Code 128

K

C

Code 39

M

A

Code 93

L

G

Code 32

M

A

Code 11

O

H

Codabar

N

F

Plessey

P

P

MSI / Plessey

a

M

Interleaved 2 of 5

I

I

IATA 2 of 5

Z

R

Matrix 2 of 5

G

X

Straight 2 of 5

S

S

Pharmacode

H

X

GS1 DataBar 14

RS

e

GS1 DataBar Expanded

RX

e

GS1 DataBar Limited

RL

e

Composite CC-A

m

e

Composite CC-B

n

e

Composite CC-C

i

e

PDF417

r

L

Micro PDF417

s

L

Data Matrix

t

d

QR Code

u

Q

Micro QR

j

Q

Aztec

e

Z

MaxiCode

v

U

Terminator#

Important

For this procedure, perform settings in the order: Start Setup -> Function Setting Barcode -> End Setup.

../../_shared/_images/module-280/TC01.png

none#

../../_shared/_images/module-280/TC03.png

* Carriage Return / CR#

../../_shared/_images/module-280/TC02.png

CR / LF#

../../_shared/_images/module-280/TC04.png

TAB#